As a basis for planning maintenance measures for an existing avalanche gallery, the avalanche effects were updated in accordance with FEDRO guideline 12007:2007 based on the SIA 269 standard for existing structures. Two options in SIA 269 were used to update design variables: 1) redetermination of the design values based on a risk-based determination of the target failure probability for the structure and 2) consideration of additional information to update the characteristic values.
Technical risk and reliability analysis
At Matrisk, we combine scientific excellence with a hands-on approach to support our clients.
Matrisk GmbH
Alte Obfelderstrasse 50
CH-8910 Affoltern am Albis
Switzerland